I was struck past times the demand for an FDA announcement to users of duodenoscopes—the endoscopes used inward endoscopic retrograde cholangiopancreatographies, or ERCPs--that they should go extra careful close cleaning the scopes to avoid transmittal of drug resistant bugs.

So I asked a friend who is a globe skilful inward ERCPs.  This MD said, "This is specific to ERCP scopes every bit an enclosed wire channel for the lift makes access hard despite next all manufacturer's recommendations.  We have got been aware of this as well as rattling proactive for a long time."

Well, as well as now, according to an article past times Steven Ross Johnson at Modern Healthcare, the folks at UCLA nation the FDA recommendation may non exercise the trick:

The FDA advised that strict adherence to manufacturers' instructions would minimize the conduct a opportunity of infection.

But according to Dr. Zachary Rubin, UCLA Medical's managing director of clinical epidemiology as well as infection prevention, his hospital's bacteria outbreak as well as several others involving duodenoscopes advise the occupation may prevarication amongst the recommendations from production makers.

UCLA officials said their investigation flora no deficiencies inward the facility's internal cleaning processes for the devices as well as that the staff fully adhered to the manufacturer's recommendations on properly sterilizing them.

“The fact that we've identified this infection inward a pair of unlike hospitals forthwith suggests that the routine physical care for nosotros were using was merely non quite adequate fifty-fifty though at the fourth dimension they were FDA approved,” Rubin said.


After Jan. 28, the infirmary began using to a greater extent than stringent sterilizing measures as well as has seen no subsequent cases of infection.


Wow.  The questions this raises teach on as well as on.

How tin forcefulness out the device have got been allowed on the marketplace past times the FDA without a thorough review of this issue?  After all, it is good known that the compass is going to locomote through the breadbasket as well as beyond each fourth dimension it is used.  Why wouldn't the way insist that the manufacturer's recommendation close sterilization at the fourth dimension the production entered the marketplace go sufficient?

If, every bit UCLA suggests, the the manufacturer's recommendation are non sufficient, why is the FDA non insisting on to a greater extent than rigorous approaches fifty-fifty now?

If some people inward the champaign already recognized this problem, similar my friend, why didn't the GI medical association promulgate the intelligence to its members?  It merely published this johnny-come-lately article.  This mightiness go a goodness fourth dimension to inquire whether the AGA or its faculty have funding from compass equipment manufacturers.  Of course of instruction they do, every bit noted here.

At what signal should the FDA recognize a occupation as well as shipping out an advisory?  It notes, "In total, from Jan 2013 through Dec 2014, the FDA received 75 MDRs encompassing unopen to 135 patients inward the USA relating to possible microbial transmission from reprocessed duodenoscopes." What is the appropriate criterion of review as well as activity inward such matters?

The FDA said:

The way is continuing to evaluate data close documented as well as potential infections from multiple sources, including Medical Device Reports (MDRs) submitted to the FDA, the medical literature, the wellness tending community, professional person medical societies, as well as the Centers for Disease Control as well as Prevention (CDC).

But here's a poster from the University of Pittsburgh suggesting that the park aeroplane of disinfection was known to go inadequate.  Amusingly, ane manufacturer, Olympus, suggested that the failure to build clean was from role of a competitor's compass washer.  The investigators found, to the contrary, that this was non the cause, as well as that a higher aeroplane of disinfection than recommended past times Olympus was necessary to avoid the transmittal of bacteria.

So, people knew close this problem:  MDs, the AGA, the FDA, the manufacturers.  Everybody but you lot as well as me.  If you lot teach to Wikipedia, bacterial infection isn't fifty-fifty included every bit a mutual conduct a opportunity of the procedure.


I wonder if the "informed consents" used past times GI doctors have got included this other risk.  That University of Pittsburgh newspaper noted: "Post-ERCP bloodstream infections (BSI’s) as well as biliary tree infections are reported later 1-3% of procedures."

I fearfulness nosotros have got been allow downwards past times the profession, the equipment manufacturers, as well as their regulators.